Analogue Productions Ultimate Analogue Test LP for precise turntable setup ! (Analogue Productions Ultimate Analogue Test LP for precise turntable setup !)
商品画像一覧
商品説明
※アメリカの現地出品者により作成されたため、英語のまま掲載いたしております。
Analogue Productions set out to produce the ultimate test record.We’ve consulted many experts in the field, including mastering engineers, audio experts, turntable experts and audiophile listeners, to create a test record thats never been made before. When Barry Wolifson from Sterling Sound in New York City called us with the same idea we had been thinking about that being to create the ultimate test record he and our audio expert Clark Williams began to brainstorm and research ideas until they were both completely satisfied with what should go on the record.Most of the test records in the past have been made to test a variety of equipment. This test record excludes silly cannon shots, typewriters, voices on one channel and other useless fluff. This one specifically addresses your turntable and cartridge. It’s designed to provide the basic test signals necessary to calibrate a turntable or cutting lathe as simply as possible. Most of the signals have specific implications, but it is certainly possible to use them in any number of novel ways.This record was mastered and cut on a Neumann VMS 80 lathe at Sterling Sound and pressed at Record Technology, Inc. on high-quality, 180-gram virgin vinyl.Side 1General Reference LevelThis 1 kHz reference tone will allow you to establish a “base level” for all measurements.Track 1 1Khz reference tone 7cm/s Mono, in phase (Lateral)Basic reference for all measurements, adjust meter for maximum convenience (in the studio 0VU).Adjust preamp channel balance for equal output.Also used to check the offset angle of the photo cartridge; L&R signals should be exactly in phase as displayed on an oscilloscope.Azimuth AdjustmentTrack 2 1kHz reference level Left channel onlyMeasure Right channel output.Track 3 1kHz reference level Right channel onlyMeasure Left channel output.The object is to sit the stylus exactly perpendicular in the groove.Twist cartridge about its radial axis until the measurements from Track 2 and Track 3 are equal or very close to equal for both channels.High Frequency AdjustmentTracks 4, 5 and 6 are used to calibrate the RIAA high frequency equalizer of a phono preamp. This will be used to calibrate a mastering lathe’s phono preamplifier or any phono preamplifier that has these adjustments.Track 4 1 kHz tone at -20 below reference level, LateralReference for High Frequency test.Track 5 10 kHz reference tone at -20dbu, LateralAdjust the high frequency until the output level equals that of Track 4.Track 6 1 kHz to 20 kHz sweep at -20dbu, Mono (Lateral)The AC millivoltmeter reading should stay constant across all frequencies. There are a number of factors which can affect frequency response, including cable capacitance, cartridge loading, tracking force and worn parts. Because of this, it can be difficult to achieve perfectly flat frequency response. Sometimes by making small compromises in the 10 kHz adjustment, a better overall frequency response can be achieved.Low Frequency AdjustmentTracks 7 & 8 are used to calibrate the RIAA low frequency equalizer of a phono preamp.Track 7 1 kHz to 20 Hz sweep at 0 VU (Lateral)Play Track 7 and measure the output with your AC millivolt meter.Ideally, the output will be flat across all frequencies. When viewed on an oscilloscope, the amplitude would remain constant during the frequency downsweep.Track 8 100 Hz reference tone at 0 vu (Lateral)Adjust LF Eq to reference (which is your reading from Track 1).Track 9 VTA adjustThis is an IEC intermodulation distortion (IMD) test signal; 60Hz & 4kHz 4:1 ratio.Using an IMD tester, adjust VTA by raising or lowering the tonearm for minimum distortion.Track 10 Standard Wow & Flutter test signal; 3150HzThe Wow & Flutter meter will give dynamic speed variations as a percentage deviation from nominal.Also, the frequency counter should read exactly 3150 Hz for nominal speed. You can use the Hz function on your multi-meter (if so equipped) to verify speed here as well. You can also use to find the measurements at 45RPM. The correct reading at 45RPM would be 4253 Hz (45/33.33) x 3150.Side 2Track 1 Anti-skating test; 315Hz amplitude sweep to +12dbu (Lateral)Signal should remain clean in both channels up to the highest level, both audibly and as viewed on an oscilloscope. In case of distortion, increase anti-skating force or decrease anti-skate until breakup occurs equally in both channels. The left channel information is inscribed on the inner groove wall, the right channel information, on the outer groove wall. Because of the offset angle of a pivoted tonearm, a constantly varying vector force biases the arm towards the center of the record causing the stylus to lose contact with the outer (i.e. right channel) groove wall. Both linear and modulated groove velocity, tracking force, stylus profile, and vinyl composition are contributing factors. The anti skating force attempts to ameliorate this by applying an opposing similar force.It is also accepted that the overall force vector increases as the tonearm approaches closer to the spindle or end of the record.Track 2 Pink noise lateralTrack 3 Pink noise verticalUsed for cartridge “demagnetizing”You can also use this track to loosen up the cantilever’s suspension to help break in a new cartridge. Play these tracks five to ten times after every 300 hours of normal LP playback.Track 4 1kHz @ reference level, verticalThis out-of-phase signal should cancel to nothing when summed to mono.Any signals still present are distortion artifacts, lack of channel balance, or timing (phase) anomalies. This test can be a second confirmation of anti-skate adjustment.Track 5 1kHz to 10Hz sweep @ -20 belowreference level, verticalResonance anomalies in the tonearm / cartridge interface will show up as amplitude peaks and dips as the frequency sweeps down.Once again, by listening in ‘Mono’ it is easier to hear the distortion artifacts.Track 6 Silent groove for bearing rumble and table isolationDuring playback of this track, nothing should be transmitted from the turntable to the speakers. Replay the track and gently tap on the rack or base that the turntable is resting on. There should be little or no thump transferred to the speakers. This track will help you experiment with turntable isolation methods and products to be able to get the most out of your playback system. You may want to use a closed or sealed headphone for best listening results, or a stethoscope on the plinth.Produced by Clark Williams and Barry WolifsonCut at Sterling Sound on a Neumann VMS-80 cutting lathe with a newly rebuilt SX-74 cutterheadTrack list: Side 1: 1. 1 kHz reference tone 7cm/s lateral in phase (mono) 2. 1 kHz reference level, left channel only 3. 1 kHz reference level, right channel only 4. 1 kHz tone at -20dB below reference level, lateral 5. 10 kHz reference tone at -20dB, lateral 6. 1 kHz to 20 kHz sweep at -20dB, lateral 7. 1 kHz to 20 Hz sweep at 0VU, lateral 8. 100 Hz reference tone at 0VU, lateral 9. VTA adjust 10. Standard Wow & Flutter test signal; 3150 Hz Side 2: 1. Anti-skating test; 315 Hz amplitude sweep to +12dB, lateral 2. Pink noise lateral 3. Pink noise vertical 4. 1 kHz at reference level, vertical 5. 1 kHz to 10 Hz sweep at -20dB below reference level, vertical 6. Silent groove for bearing rumble and table isolation
商品説明
(Analogue Productions Ultimate Analogue Test LP for precise turntable setup !)
Analogue Productions set out to produce the ultimate test record.We’ve consulted many experts in the field, including mastering engineers, audio experts, turntable experts and audiophile listeners, to create a test record thats never been made before. When Barry Wolifson from Sterling Sound in New York City called us with the same idea we had been thinking about that being to create the ultimate test record he and our audio expert Clark Williams began to brainstorm and research ideas until they were both completely satisfied with what should go on the record.Most of the test records in the past have been made to test a variety of equipment. This test record excludes silly cannon shots, typewriters, voices on one channel and other useless fluff. This one specifically addresses your turntable and cartridge. It’s designed to provide the basic test signals necessary to calibrate a turntable or cutting lathe as simply as possible. Most of the signals have specific implications, but it is certainly possible to use them in any number of novel ways.This record was mastered and cut on a Neumann VMS 80 lathe at Sterling Sound and pressed at Record Technology, Inc. on high-quality, 180-gram virgin vinyl.Side 1General Reference LevelThis 1 kHz reference tone will allow you to establish a “base level” for all measurements.Track 1 1Khz reference tone 7cm/s Mono, in phase (Lateral)Basic reference for all measurements, adjust meter for maximum convenience (in the studio 0VU).Adjust preamp channel balance for equal output.Also used to check the offset angle of the photo cartridge; L&R signals should be exactly in phase as displayed on an oscilloscope.Azimuth AdjustmentTrack 2 1kHz reference level Left channel onlyMeasure Right channel output.Track 3 1kHz reference level Right channel onlyMeasure Left channel output.The object is to sit the stylus exactly perpendicular in the groove.Twist cartridge about its radial axis until the measurements from Track 2 and Track 3 are equal or very close to equal for both channels.High Frequency AdjustmentTracks 4, 5 and 6 are used to calibrate the RIAA high frequency equalizer of a phono preamp. This will be used to calibrate a mastering lathe’s phono preamplifier or any phono preamplifier that has these adjustments.Track 4 1 kHz tone at -20 below reference level, LateralReference for High Frequency test.Track 5 10 kHz reference tone at -20dbu, LateralAdjust the high frequency until the output level equals that of Track 4.Track 6 1 kHz to 20 kHz sweep at -20dbu, Mono (Lateral)The AC millivoltmeter reading should stay constant across all frequencies. There are a number of factors which can affect frequency response, including cable capacitance, cartridge loading, tracking force and worn parts. Because of this, it can be difficult to achieve perfectly flat frequency response. Sometimes by making small compromises in the 10 kHz adjustment, a better overall frequency response can be achieved.Low Frequency AdjustmentTracks 7 & 8 are used to calibrate the RIAA low frequency equalizer of a phono preamp.Track 7 1 kHz to 20 Hz sweep at 0 VU (Lateral)Play Track 7 and measure the output with your AC millivolt meter.Ideally, the output will be flat across all frequencies. When viewed on an oscilloscope, the amplitude would remain constant during the frequency downsweep.Track 8 100 Hz reference tone at 0 vu (Lateral)Adjust LF Eq to reference (which is your reading from Track 1).Track 9 VTA adjustThis is an IEC intermodulation distortion (IMD) test signal; 60Hz & 4kHz 4:1 ratio.Using an IMD tester, adjust VTA by raising or lowering the tonearm for minimum distortion.Track 10 Standard Wow & Flutter test signal; 3150HzThe Wow & Flutter meter will give dynamic speed variations as a percentage deviation from nominal.Also, the frequency counter should read exactly 3150 Hz for nominal speed. You can use the Hz function on your multi-meter (if so equipped) to verify speed here as well. You can also use to find the measurements at 45RPM. The correct reading at 45RPM would be 4253 Hz (45/33.33) x 3150.Side 2Track 1 Anti-skating test; 315Hz amplitude sweep to +12dbu (Lateral)Signal should remain clean in both channels up to the highest level, both audibly and as viewed on an oscilloscope. In case of distortion, increase anti-skating force or decrease anti-skate until breakup occurs equally in both channels. The left channel information is inscribed on the inner groove wall, the right channel information, on the outer groove wall. Because of the offset angle of a pivoted tonearm, a constantly varying vector force biases the arm towards the center of the record causing the stylus to lose contact with the outer (i.e. right channel) groove wall. Both linear and modulated groove velocity, tracking force, stylus profile, and vinyl composition are contributing factors. The anti skating force attempts to ameliorate this by applying an opposing similar force.It is also accepted that the overall force vector increases as the tonearm approaches closer to the spindle or end of the record.Track 2 Pink noise lateralTrack 3 Pink noise verticalUsed for cartridge “demagnetizing”You can also use this track to loosen up the cantilever’s suspension to help break in a new cartridge. Play these tracks five to ten times after every 300 hours of normal LP playback.Track 4 1kHz @ reference level, verticalThis out-of-phase signal should cancel to nothing when summed to mono.Any signals still present are distortion artifacts, lack of channel balance, or timing (phase) anomalies. This test can be a second confirmation of anti-skate adjustment.Track 5 1kHz to 10Hz sweep @ -20 belowreference level, verticalResonance anomalies in the tonearm / cartridge interface will show up as amplitude peaks and dips as the frequency sweeps down.Once again, by listening in ‘Mono’ it is easier to hear the distortion artifacts.Track 6 Silent groove for bearing rumble and table isolationDuring playback of this track, nothing should be transmitted from the turntable to the speakers. Replay the track and gently tap on the rack or base that the turntable is resting on. There should be little or no thump transferred to the speakers. This track will help you experiment with turntable isolation methods and products to be able to get the most out of your playback system. You may want to use a closed or sealed headphone for best listening results, or a stethoscope on the plinth.Produced by Clark Williams and Barry WolifsonCut at Sterling Sound on a Neumann VMS-80 cutting lathe with a newly rebuilt SX-74 cutterheadTrack list: Side 1: 1. 1 kHz reference tone 7cm/s lateral in phase (mono) 2. 1 kHz reference level, left channel only 3. 1 kHz reference level, right channel only 4. 1 kHz tone at -20dB below reference level, lateral 5. 10 kHz reference tone at -20dB, lateral 6. 1 kHz to 20 kHz sweep at -20dB, lateral 7. 1 kHz to 20 Hz sweep at 0VU, lateral 8. 100 Hz reference tone at 0VU, lateral 9. VTA adjust 10. Standard Wow & Flutter test signal; 3150 Hz Side 2: 1. Anti-skating test; 315 Hz amplitude sweep to +12dB, lateral 2. Pink noise lateral 3. Pink noise vertical 4. 1 kHz at reference level, vertical 5. 1 kHz to 10 Hz sweep at -20dB below reference level, vertical 6. Silent groove for bearing rumble and table isolation
弊社ショップでは、クレジットカード決済またはPayPay残高払いのみ対応しております。
万が一、お支払いの確認ができない場合には、購入のご意思が無いものとして、お取り引きをキャンセルとする場合がございます。予めご了承ください。
ヤフオク!セカイモン店で落札いただいた商品は、全て送料無料でお届けしております。
落札金額以外にお支払いいただく費用はございませんので、ご安心くださいませ。
ヤフオク!セカイモン店で落札いただいた商品は、個人使用を前提として商品の通関を行っております。
東京税関の指導により、個人輸入の配送先はお客様(輸入者)のご自宅住所1か所で、個人の氏名に限定されております。
よって商品の配送先は、個人の住所を登録してください。住所が会社や法人、団体などの場合は商用とみなされ、通関できない恐れがあります。
そのため、配送先が個人の自宅住所以外になる場合は、購入はお控えください。
落札成立後、出品者とのお取引が開始しているのでキャンセルはできません。
商品情報を十分にご確認いただいたうえで、商品を落札いただけますようお願いいたします。